Exam 6: Digital Fluoroscopy
Exam 1: Digital Radiography: An Overview50 Questions
Exam 2: Digital Imaging Processing Concepts50 Questions
Exam 3: Computed Radiography: Physics and Technology50 Questions
Exam 4: Effective Use of Computed Radiography50 Questions
Exam 5: Flat-Panel Digital Radiography50 Questions
Exam 6: Digital Fluoroscopy50 Questions
Exam 7: Digital Mammography50 Questions
Exam 8: Picture Archiving and Communication Systems50 Questions
Exam 9: Medical Imaging Informatics: An Overview50 Questions
Exam 10: Quality Control for Digital Radiography50 Questions
Select questions type
The ____________________ operation is based on subtraction of images taken at different kVs.
Free
(Short Answer)
4.9/5
(33)
Correct Answer:
energy subtraction
Through the years, fluoroscopy has developed into a sophisticated imaging system as new technologies have emerged to improve its imaging system characteristics.
Free
(True/False)
4.9/5
(42)
Correct Answer:
True
____ uses an image intensifier coupled to a video camera that converts the image from the output screen of the image intensifier into a video signal.
Free
(Multiple Choice)
4.9/5
(41)
Correct Answer:
A
Conventional fluoroscopy with an image intensifier operates in the low mA mode, and therefore the noise level is usually high.
(True/False)
4.8/5
(40)
____ is the continued emission of light from the screen when the radiation beam has been turned off.
(Multiple Choice)
4.8/5
(39)
The X-ray tube used in fluoroscopy must be capable of producing X-rays either continuously or in long series.
(True/False)
4.8/5
(37)
In digital fluoroscopy, the display image receives the video signal from the video camera and with suitable electronics, uses the signal to create the television image.
(True/False)
4.7/5
(34)
The ____________________ ratio of an image intensifier tube is the ratio of the image brightness at the periphery to that at the center of the output screen.
(Short Answer)
4.8/5
(45)
The energy subtraction operation is based on subtraction of images taken at different ___________________.
(Short Answer)
5.0/5
(32)
In fluoroscopy, a ____ converts the light from the output screen of the image intensifier into an electrical signal (output video signal), which is sent to the television monitor where it is converted into a visible image that can be viewed in real time.
(Multiple Choice)
4.8/5
(31)
Early fluoroscopy had to be performed in the dark using ____ for dark adaptation.
(Multiple Choice)
4.8/5
(35)
All digital imaging modalities, including digital fluoroscopy, make use of various types of image post-processing algorithms (software), essentially to manipulate the image presented to the observer in order to enhance diagnostic ____________________.
(Short Answer)
4.8/5
(45)
At the heart of a digital fluoroscopy imaging system is a(n)____________________ computer, a minicomputer system capable of receiving dynamic digital data from the ADC and processing it quickly for image display and subsequent storage.
(Short Answer)
4.8/5
(37)
A(n)____ couples the video camera to the television monitor by means of a coaxial cable and control electronics.
(Multiple Choice)
4.9/5
(36)
In some systems, it is possible to adjust the pixel size by ____________________ four pixels into one larger pixel.
(Short Answer)
4.9/5
(34)
A digital image is made up of a matrix of pixels in which each pixel is assigned a number and each number corresponds to a(n)____________________.
(Short Answer)
4.8/5
(46)
The ____________________ is a high-frequency generator and can provide the high mA values used in digital fluoroscopy, as opposed to the low mA values typical of conventional fluoroscopy.
(Short Answer)
5.0/5
(39)
Digital fluoroscopy can be applied to both gastrointestinal (GI)tract imaging and DSA, and the image ____________________ operations are specific to each application.
(Short Answer)
4.8/5
(26)
The exposure rate for a ____ cm mode is about 30
while it is 60 11ec6bd3_b879_2049_bb89_052ef0a603dd_TB2055_11 , and 120 11ec6bd3_b879_2049_bb89_052ef0a603dd_TB2055_11 for the 17 cm and 12 cm modes respectively

(Multiple Choice)
4.8/5
(25)
DSA has advanced from film-based imaging using image intensifier/video camera technology to imaging with dynamic FPDs.
(True/False)
4.8/5
(31)
Showing 1 - 20 of 50
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)