Exam 4: Effective Use of Computed Radiography
Exam 1: Digital Radiography: An Overview50 Questions
Exam 2: Digital Imaging Processing Concepts50 Questions
Exam 3: Computed Radiography: Physics and Technology50 Questions
Exam 4: Effective Use of Computed Radiography50 Questions
Exam 5: Flat-Panel Digital Radiography50 Questions
Exam 6: Digital Fluoroscopy50 Questions
Exam 7: Digital Mammography50 Questions
Exam 8: Picture Archiving and Communication Systems50 Questions
Exam 9: Medical Imaging Informatics: An Overview50 Questions
Exam 10: Quality Control for Digital Radiography50 Questions
Select questions type
Since the image contrast is generally determined more by the processing algorithm, the ____________________ does not have the impact on final image contrast as with screen/film systems.
Free
(Short Answer)
5.0/5
(38)
Correct Answer:
kVp
____ occurs when a large number of the pixels will be at the maximum digital value (black)so that there is no signal difference in the very high exposure areas, resulting in a loss of anatomical structures in that region.
Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
B
Because of the light spread between the plate and the light guide, the spatial resolution is less than the ____________________ frequency.
Free
(Short Answer)
4.7/5
(39)
Correct Answer:
Nyquist
If a vendor provides a fixed-speed class operation, the system operates as a screen/film system of the selected ____________________.
(Short Answer)
4.9/5
(37)
Because of the increased sensitivity to scattered radiation, the kVp should not exceed ____ for any nongrid radiography, including chest.
(Multiple Choice)
4.8/5
(29)
With cassette-based PSP systems (CR), ____________________ resolution becomes a bit more complicated.
(Short Answer)
4.8/5
(37)
If larger body structures are done 3 on 1, the ____________________ scatter will reduce the contrast unless the unexposed areas are shielded between exposures.
(Short Answer)
4.8/5
(36)
The CR cassettes, or imaging plates (IP), are employed in the same manner as screen/film cassettes in existing radiographic units designed to accommodate software.
(True/False)
4.9/5
(45)
Because of their wide dynamic range, PSP plates are much more susceptible to ____________________ than are conventional film-screen systems.
(Short Answer)
4.7/5
(38)
The optimal alignment for all digital detectors is to have the part and beam centered to the receptor, with four collimation margins perpendicular to the cassette edges.
(True/False)
4.7/5
(29)
The factors determining ____________________ included motion factors, geometric factors, and the spatial resolution of the receptor unit (line pair/mm).
(Short Answer)
4.9/5
(33)
Many of the factors that cause low contrast in film-screen systems also cause low contrast in CR images.
(True/False)
4.9/5
(32)
Which exposure causes the system to rescale the image as if the plate is actually underexposed?
(Multiple Choice)
4.9/5
(36)
What is likely to occur if there is substantial extraneous exposure on the plate?
(Multiple Choice)
4.8/5
(34)
By reducing the acquired data width, more of the ____________________ may be visualized for a single image display setting.
(Short Answer)
4.9/5
(27)
What limits the irradiated volume and reduces undercutting?
(Multiple Choice)
4.8/5
(30)
With digital systems, what determines the speed class at which the system is operated?
(Multiple Choice)
5.0/5
(35)
What does it mean when the photon intensity reaching the receptor is lower than that required to produce an optimal image?
(Multiple Choice)
4.8/5
(28)
____________________ exposures are dramatically affected by the additional scatter, which may not even be removable by a grid.
(Short Answer)
4.8/5
(35)
Which of the following has more of an effect on image contrast than the kVp?
(Multiple Choice)
4.9/5
(31)
Showing 1 - 20 of 50
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)