Since the image contrast is generally determined more by the processing algorithm, the ____________________ does not have the impact on final image contrast as with screen/film systems.

Free
(Short Answer)
5.0/5
(38)
Correct Answer:
Verified

kVp

____ occurs when a large number of the pixels will be at the maximum digital value (black)so that there is no signal difference in the very high exposure areas, resulting in a loss of anatomical structures in that region.

Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
Verified

B

Because of the light spread between the plate and the light guide, the spatial resolution is less than the ____________________ frequency.

Free
(Short Answer)
4.7/5
(39)
Correct Answer:
Verified

Nyquist

If a vendor provides a fixed-speed class operation, the system operates as a screen/film system of the selected ____________________.

(Short Answer)
4.9/5
(37)

Because of the increased sensitivity to scattered radiation, the kVp should not exceed ____ for any nongrid radiography, including chest.

(Multiple Choice)
4.8/5
(29)

With cassette-based PSP systems (CR), ____________________ resolution becomes a bit more complicated.

(Short Answer)
4.8/5
(37)

If larger body structures are done 3 on 1, the ____________________ scatter will reduce the contrast unless the unexposed areas are shielded between exposures.

(Short Answer)
4.8/5
(36)

The CR cassettes, or imaging plates (IP), are employed in the same manner as screen/film cassettes in existing radiographic units designed to accommodate software.

(True/False)
4.9/5
(45)

Because of their wide dynamic range, PSP plates are much more susceptible to ____________________ than are conventional film-screen systems.

(Short Answer)
4.7/5
(38)

The optimal alignment for all digital detectors is to have the part and beam centered to the receptor, with four collimation margins perpendicular to the cassette edges.

(True/False)
4.7/5
(29)

The factors determining ____________________ included motion factors, geometric factors, and the spatial resolution of the receptor unit (line pair/mm).

(Short Answer)
4.9/5
(33)

Many of the factors that cause low contrast in film-screen systems also cause low contrast in CR images.

(True/False)
4.9/5
(32)

Which exposure causes the system to rescale the image as if the plate is actually underexposed?

(Multiple Choice)
4.9/5
(36)

What is likely to occur if there is substantial extraneous exposure on the plate?

(Multiple Choice)
4.8/5
(34)

By reducing the acquired data width, more of the ____________________ may be visualized for a single image display setting.

(Short Answer)
4.9/5
(27)

What limits the irradiated volume and reduces undercutting?

(Multiple Choice)
4.8/5
(30)

With digital systems, what determines the speed class at which the system is operated?

(Multiple Choice)
5.0/5
(35)

What does it mean when the photon intensity reaching the receptor is lower than that required to produce an optimal image?

(Multiple Choice)
4.8/5
(28)

____________________ exposures are dramatically affected by the additional scatter, which may not even be removable by a grid.

(Short Answer)
4.8/5
(35)

Which of the following has more of an effect on image contrast than the kVp?

(Multiple Choice)
4.9/5
(31)