Exam 29: Configuring a Usb Driver for a 1756-En2t Ethernet Communications Module
Exam 1: Introduction to Control Logix Hardware14 Questions
Exam 2: Introduction to Rs Logix 5000 Software19 Questions
Exam 3: Number Systems17 Questions
Exam 4: Rs Logix 5000 Project Organization16 Questions
Exam 5: Understanding Control Logix I-O Addressing16 Questions
Exam 6: Modular Controllogix Digital and Analog I-O Configuration15 Questions
Exam 7: Compactlogix I-O Configuration15 Questions
Exam 8: Communicating Between Your Personal Computer and Your Plc15 Questions
Exam 9: Creating and Monitoring Rs Logix 5000 Tags15 Questions
Exam 10: Introduction to Logic15 Questions
Exam 11: The Basic Relay Instructions15 Questions
Exam 12: Controllogix Timer Instructions15 Questions
Exam 13: Adding Ladder Rung Documentation15 Questions
Exam 14: Control Logix Counter Instructions15 Questions
Exam 15: Comparison Instructions15 Questions
Exam 16: Data-Handling Instructions15 Questions
Exam 17: Introduction to the Get System Values Gsv and Set Systems Values Ssv Instructions15 Questions
Exam 18: Introduction to the Rs Logix 5000 Function Block Programming Language15 Questions
Exam 19: Configuring a Serial Driver Using Rs Linx15 Questions
Exam 20: Configuring the Keyspan by Tripp Lite, High-Speed Usb to Serial Adapter Model Usa-19hs15 Questions
Exam 21: Configuring an Rslinx Serial Driver Using a Rockwell Automation 9300-Usbs Usb to Serial Adapter15 Questions
Exam 22: Installing and Configuring a Usb Driver for 1756-L7 Series Controllers15 Questions
Exam 23: Determining and Modifying a Personal Computers Ip Address15 Questions
Exam 24: Configuring 1756 Control Logix Modular Ethernet Hardware15 Questions
Exam 25: Configuring the Ethernet Ip Address for a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e15 Questions
Exam 26: Configuring a 1756-Enet Ethernet Driver Using Rs Linx10 Questions
Exam 27: Configuring Ethernet-Ip Drivers Using Rs Linx Software15 Questions
Exam 28: Configuring a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e Ethernet-Ip Driver Using Rslinx15 Questions
Exam 29: Configuring a Usb Driver for a 1756-En2t Ethernet Communications Module12 Questions
Select questions type
If you have a personal computer with no standard serial port but with USB ports, and a ControlLogix controller with a traditional 9-pin D-shell serial port, direct serial communication between the personal computer and the ControlLogix controller will be very easy.
Free
(True/False)
4.9/5
(34)
Correct Answer:
False
If the USB driver is configured in conjunction with the USB port configuration of the personal computer, the driver cannot be reconfigured in ____________________.
Free
(Short Answer)
4.7/5
(28)
Correct Answer:
RSLinx
In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, what are two other methods by which the module's IP address can be configured?
Free
(Essay)
5.0/5
(33)
Correct Answer:
In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, the module's IP address can also be configured using RSLogix 5000 or RSLinx software.
The three switches on top of the 1756-EN2T module can be modified before or after installing the module in a chassis.
(True/False)
4.7/5
(38)
When a new device is connected to a personal computer, the Found New Hardware Wizard can assist with installing driver software automatically.
(True/False)
4.8/5
(33)
To download an RSLogix project to a ControlLogix controller, the project must be saved and closed.
(True/False)
4.7/5
(32)
When a ControlLogix module with an integrated USB port is being used for the first time with a particular computer, the required USB drivers must be configured.
(True/False)
4.8/5
(37)
With the RSLinx driver configured, a RSLogix 5000 project can be downloaded from the personal computer to the ControlLogix controller by way of the 1756-EN2T's USB port.
(True/False)
4.9/5
(44)
List three points to keep in mind for using USB communications between a personal computer and a ControlLogix Communications Module.
(Essay)
4.9/5
(37)
Typically, the personal computer USB driver configuration only has to be completed once.
(True/False)
4.8/5
(35)
List two examples of features supported by newer modular ControlLogix Ethernet/IP communications modules.
(Essay)
4.7/5
(25)
If the switches of the 1756-EN2T are set for a specific address, this IP address can be changed in the module's configuration window in RSLinx.
(True/False)
4.9/5
(39)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)