Exam 29: Configuring a Usb Driver for a 1756-En2t Ethernet Communications Module

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

If you have a personal computer with no standard serial port but with USB ports, and a ControlLogix controller with a traditional 9-pin D-shell serial port, direct serial communication between the personal computer and the ControlLogix controller will be very easy.

Free
(True/False)
4.9/5
(34)
Correct Answer:
Verified

False

If the USB driver is configured in conjunction with the USB port configuration of the personal computer, the driver cannot be reconfigured in ____________________.

Free
(Short Answer)
4.7/5
(28)
Correct Answer:
Verified

RSLinx

In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, what are two other methods by which the module's IP address can be configured?

Free
(Essay)
5.0/5
(33)
Correct Answer:
Verified

In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, the module's IP address can also be configured using RSLogix 5000 or RSLinx software.

The three switches on top of the 1756-EN2T module can be modified before or after installing the module in a chassis.

(True/False)
4.7/5
(38)

When a new device is connected to a personal computer, the Found New Hardware Wizard can assist with installing driver software automatically.

(True/False)
4.8/5
(33)

To download an RSLogix project to a ControlLogix controller, the project must be saved and closed.

(True/False)
4.7/5
(32)

When a ControlLogix module with an integrated USB port is being used for the first time with a particular computer, the required USB drivers must be configured.

(True/False)
4.8/5
(37)

With the RSLinx driver configured, a RSLogix 5000 project can be downloaded from the personal computer to the ControlLogix controller by way of the 1756-EN2T's USB port.

(True/False)
4.9/5
(44)

List three points to keep in mind for using USB communications between a personal computer and a ControlLogix Communications Module.

(Essay)
4.9/5
(37)

Typically, the personal computer USB driver configuration only has to be completed once.

(True/False)
4.8/5
(35)

List two examples of features supported by newer modular ControlLogix Ethernet/IP communications modules.

(Essay)
4.7/5
(25)

If the switches of the 1756-EN2T are set for a specific address, this IP address can be changed in the module's configuration window in RSLinx.

(True/False)
4.9/5
(39)