Exam 28: Configuring a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e Ethernet-Ip Driver Using Rslinx

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

One feature of the newer Ethernet/IP driver is that RSLinx browses the local subnet, automatically finds devices with compatible IP addresses, and then finishes configuring the driver for you.

Free
(True/False)
4.9/5
(34)
Correct Answer:
Verified

True

In the Configure Drivers window, the driver that can only be used to configure a driver for the newer modular Ethernet/IP communications modules for the modular ControlLogix chassis and CompactLogix with Ethernet/IP. is the ____________________ driver.

Free
(Short Answer)
4.7/5
(44)
Correct Answer:
Verified

Ethernet/IP

In the Configure Drivers window, the word "running" listed twice for a configured driver verifies communication with the target device.

Free
(True/False)
4.8/5
(35)
Correct Answer:
Verified

False

The Ethernet driver for the CompactLogix Ethernet controller must be configured prior to configuring the personal computer with which communication is desired.

(True/False)
4.9/5
(32)

If communication was lost between your computer and the Ethernet communications module after the driver has been successfully configured, an X will display on top of the module's icon,

(True/False)
4.8/5
(34)

After a driver has been configured, open the ____________________ window to verify communication has been established with the target device.

(Short Answer)
4.7/5
(36)

In the event of a failed attempt to configure a driver for an Ethernet module, what is a simple error that may have occurred?

(Essay)
4.9/5
(32)

If desired, the default driver name provided by RSLinx during configuration can be changed in the Add New RSLinx Classic Driver window.

(True/False)
4.9/5
(45)

What steps can be taken if the word "running" is not listed twice for a configured Ethernet driver in the Configure Drivers window?

(Essay)
4.9/5
(40)

When configuring a Ethernet/IP driver for a Bulletin 1769 CompactLogix controller using RSLinx, select an Ethernet crossover cable to connect the module and the personal computer.

(True/False)
4.7/5
(44)

Suppose a yellow question mark and text stating unrecognized device are displayed in the RSWho window. Briefly describe the problem and how it can likely be resolved.

(Essay)
4.8/5
(36)

The older ____________________ driver can be used to configure most Ethernet modules; however, it is typically used for the 1756-ENET module.

(Short Answer)
4.9/5
(37)

When configuring a driver for a CompactLogix Ethernet module, suppose the personal computer IP address is not available as a selection as an Ethernet interface. What are two checks that can be performed?

(Essay)
4.9/5
(42)

Manually configuring a driver using the Ethernet devices driver can be used to display only the desired Ethernet/IP devices in RSWho.

(True/False)
4.8/5
(40)

An RSLinx driver can be deleted at any time and reconfigured to resolve problems with the driver.

(True/False)
4.8/5
(33)