Exam 27: Configuring Ethernet-Ip Drivers Using Rs Linx Software

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

Manually configuring a driver using the Ethernet devices driver can be used to display only the desired Ethernet/IP devices in RSWho.

Free
(True/False)
4.7/5
(30)
Correct Answer:
Verified

True

After a driver has been configured, open the ____________________ window to verify communication has been established with the target device.

Free
(Short Answer)
4.9/5
(31)
Correct Answer:
Verified

RSWho

Suppose a yellow question mark and text stating unrecognized device are displayed in the RSWho window. Briefly describe the problem and how it can likely be resolved.

Free
(Essay)
4.7/5
(37)
Correct Answer:
Verified

In most situations where the question mark is displayed, RSLinx has identified a device on the network at the address displayed; however, RSLinx does not know (recognize) the device. Most likely the problem here is that the firmware of the Ethernet communications module is newer than the current revision of RSLinx software can recognize. Updating RSLinx to the latest software version typically takes care of the problem. Also check for proper configuration.

An RSLinx driver can be deleted at any time and reconfigured to resolve problems with the driver.

(True/False)
4.8/5
(40)

In the Configure Drivers window, the word "running" listed twice for a configured driver verifies communication with the target device.

(True/False)
4.8/5
(35)

In the Configure Drivers window, the driver that can only be used to configure modules such as 1756-ENBT, EN2T, EN2F, or newer modules is the ____________________ driver.

(Short Answer)
5.0/5
(27)

When configuring a driver for a ControlLogix Ethernet module, suppose the personal computer IP address is not available as a selection as an Ethernet interface. What are two checks that can be performed?

(Essay)
4.9/5
(43)

What steps can be taken if the word "running" is not listed twice for a configured Ethernet driver in the Configure Drivers window?

(Essay)
4.9/5
(46)

If desired, the default driver name provided by RSLinx during configuration can be changed in the RSWho window.

(True/False)
4.9/5
(42)

The 1756-ENBT Ethernet driver must be configured prior to configuring the personal computer with which communication is desired.

(True/False)
4.8/5
(36)

One feature of the newer Ethernet/IP driver is that RSLinx browses the local subnet, automatically finds devices with compatible IP addresses, and then finishes configuring the driver for you.

(True/False)
4.9/5
(35)

If communication was lost between your computer and the Ethernet communications module after the driver has been successfully configured, an X will display on top of the module's icon.

(True/False)
4.7/5
(29)

In the event of a failed attempt to configure a driver for an Ethernet module, what is a simple error that may have occurred?

(Essay)
4.8/5
(35)

The older ____________________ driver can be used to configure most Ethernet modules; however, it is typically used for the 1756-ENET module.

(Short Answer)
4.8/5
(34)

When configuring a 1756-ENBT Ethernet driver using RSLinx, select an Ethernet crossover cable to connect the module and the personal computer.

(True/False)
4.7/5
(27)
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)