Heavy-duty lighting track is identified for use exceeding ____ amperes.

Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
Verified

B

A recessed luminaire not identified for contact with insulation shall have all recessed parts spaced at least ____ from combustible materials.

Free
(Multiple Choice)
4.7/5
(34)
Correct Answer:
Verified

A

The minimum number of branch circuits is determined from ____ load and the size (or rating) of the circuits used.

Free
(Multiple Choice)
5.0/5
(47)
Correct Answer:
Verified

D

One of two methods for calculating show window branch-circuit loads is to multiply each receptacle by ____ volt-amperes.

(Multiple Choice)
4.7/5
(33)

Receptacles are calculated at ____ per strap.

(Multiple Choice)
4.7/5
(34)

A continuous load is defined as a load ____.

(Multiple Choice)
4.8/5
(33)

The ____ for the controlled lighting circuit shall be provided at the location where switches control lighting loads that are supplied by a grounded general-purpose branch circuit.

(Multiple Choice)
4.9/5
(40)

The supply circuit's calculated load for lighting units that have ballasts or transformers is based on the ____, not on the lamps' total wattage.

(Multiple Choice)
4.9/5
(27)

Sign and outline lighting outlets must be calculated at a minimum of ____ per required branch circuit.

(Multiple Choice)
4.8/5
(32)

GFCI protection for personnel is required in bathroom receptacles that are ____.

(Multiple Choice)
4.8/5
(36)

Where appliances are unlikely to be used simultaneously, each ____ or fraction thereof (of separate and continuous length) shall be considered one outlet of not less than 180 volt-amperes.

(Multiple Choice)
4.8/5
(34)

The disconnecting means for a sign in a commercial or industrial building must be ____ or outline lighting system that it controls.

(Multiple Choice)
4.8/5
(36)

Individual moveable showcases can be connected by ____.

(Multiple Choice)
4.9/5
(28)

A 3-phase, 4-wire, wye-connected power system supplying nonlinear loads may necessitate a design allowing for the possibility of ____ on the neutral conductor.

(Multiple Choice)
4.8/5
(44)

Receptacles, connectors, and attachment plugs for showcases must be of a listed grounding type, rated ____.

(Multiple Choice)
4.7/5
(40)

____ applies to the wall placement provisions for commercial occupancies.

(Multiple Choice)
4.8/5
(39)

For circuits supplying loads consisting of motor-operated utilization equipment (fastened in place with a motor larger than 1.8 hp) in combination with other loads, the total calculated load must be based on ____% of the largest motor load plus the sum of the other loads.

(Multiple Choice)
4.8/5
(31)

Branch circuits shall be rated in accordance with the maximum permitted ampere rating or setting of the ____.

(Multiple Choice)
4.8/5
(25)

Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads, the minimum branch-circuit conductor size shall have an allowable ampacity not less than the noncontinuous load plus ____ of the continuous load.

(Multiple Choice)
4.8/5
(34)

____ receptacles are permitted on a 15-ampere overcurrent protective device.

(Multiple Choice)
4.9/5
(41)