Exam 12: General Provisions
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations19 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Heavy-duty lighting track is identified for use exceeding ____ amperes.
Free
(Multiple Choice)
4.8/5
(33)
Correct Answer:
B
A recessed luminaire not identified for contact with insulation shall have all recessed parts spaced at least ____ from combustible materials.
Free
(Multiple Choice)
4.7/5
(34)
Correct Answer:
A
The minimum number of branch circuits is determined from ____ load and the size (or rating) of the circuits used.
Free
(Multiple Choice)
5.0/5
(47)
Correct Answer:
D
One of two methods for calculating show window branch-circuit loads is to multiply each receptacle by ____ volt-amperes.
(Multiple Choice)
4.7/5
(33)
The ____ for the controlled lighting circuit shall be provided at the location where switches control lighting loads that are supplied by a grounded general-purpose branch circuit.
(Multiple Choice)
4.9/5
(40)
The supply circuit's calculated load for lighting units that have ballasts or transformers is based on the ____, not on the lamps' total wattage.
(Multiple Choice)
4.9/5
(27)
Sign and outline lighting outlets must be calculated at a minimum of ____ per required branch circuit.
(Multiple Choice)
4.8/5
(32)
GFCI protection for personnel is required in bathroom receptacles that are ____.
(Multiple Choice)
4.8/5
(36)
Where appliances are unlikely to be used simultaneously, each ____ or fraction thereof (of separate and continuous length) shall be considered one outlet of not less than 180 volt-amperes.
(Multiple Choice)
4.8/5
(34)
The disconnecting means for a sign in a commercial or industrial building must be ____ or outline lighting system that it controls.
(Multiple Choice)
4.8/5
(36)
A 3-phase, 4-wire, wye-connected power system supplying nonlinear loads may necessitate a design allowing for the possibility of ____ on the neutral conductor.
(Multiple Choice)
4.8/5
(44)
Receptacles, connectors, and attachment plugs for showcases must be of a listed grounding type, rated ____.
(Multiple Choice)
4.7/5
(40)
____ applies to the wall placement provisions for commercial occupancies.
(Multiple Choice)
4.8/5
(39)
For circuits supplying loads consisting of motor-operated utilization equipment (fastened in place with a motor larger than 1.8 hp) in combination with other loads, the total calculated load must be based on ____% of the largest motor load plus the sum of the other loads.
(Multiple Choice)
4.8/5
(31)
Branch circuits shall be rated in accordance with the maximum permitted ampere rating or setting of the ____.
(Multiple Choice)
4.8/5
(25)
Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads, the minimum branch-circuit conductor size shall have an allowable ampacity not less than the noncontinuous load plus ____ of the continuous load.
(Multiple Choice)
4.8/5
(34)
____ receptacles are permitted on a 15-ampere overcurrent protective device.
(Multiple Choice)
4.9/5
(41)