Exam 10: Comprehensive Provisions

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

A single-phase feeder (or branch circuit) conductor will have a total resistance ____ that of one conductor.

Free
(Multiple Choice)
4.8/5
(28)
Correct Answer:
Verified

B

____ is the maximum number of disconnects per service grouped in any one location.

Free
(Multiple Choice)
4.8/5
(38)
Correct Answer:
Verified

C

Conductors must have ____ and sufficient ampacity to carry the current for the load as calculated.

Free
(Multiple Choice)
4.8/5
(27)
Correct Answer:
Verified

C

A drip loop's lowest point has a minimum vertical clearance of ____ ft.

(Multiple Choice)
4.7/5
(35)

A minimum of ____ wall switch-controlled lighting outlet(s) is (are) required for dwelling hallways.

(Multiple Choice)
4.9/5
(36)

General receptacle installation provisions for multifamily dwellings are almost identical to those for ____.

(Multiple Choice)
4.8/5
(33)

Dwelling-unit branch circuits shall supply only loads within, or associated only with, ____.

(Multiple Choice)
4.8/5
(31)

All electric equipment must be ____ to allow ready and safe equipment operation and maintenance.

(Multiple Choice)
4.7/5
(37)

Skin effect and induction change the resistance in alternating-current (ac) circuits, therefore resistance of a conductor is ____.

(Multiple Choice)
4.8/5
(27)

Voltage drop in a single-phase circuit can also be found using the formula ____.

(Multiple Choice)
4.8/5
(27)

A multifamily dwelling is a building containing ____ dwelling units.

(Multiple Choice)
4.9/5
(27)

The vertical clearance above roof level must be maintained for a distance of at least ____ ft from all edges of the roof.

(Multiple Choice)
4.8/5
(30)

Each occupant must have ready access to ____ protecting the conductors supplying that occupancy.

(Multiple Choice)
4.9/5
(36)

Service conductors supplying a building (or other structure) shall not ____.

(Multiple Choice)
4.8/5
(33)

The higher the resistance through a conductor, the ____.

(Multiple Choice)
4.8/5
(32)

All 125-volt, single-phase, 15- and 20-ampere dwelling unit outdoor receptacles must have ____.

(Multiple Choice)
4.8/5
(33)

On long runs, it may be necessary to ____ to compensate for voltage drop.

(Multiple Choice)
4.9/5
(37)

The maximum distance to any receptacle, measured horizontally along the wall line, is ____ in.

(Multiple Choice)
4.8/5
(35)

Kitchen receptacles not serving countertops (such as receptacles behind refrigerators) ____ unless they are installed within 6 ft of the outside edge of the sink.

(Multiple Choice)
5.0/5
(35)

The conductor voltage that is dropped is a percentage of the source voltage and can be calculated by ____.

(Multiple Choice)
4.9/5
(35)
Showing 1 - 20 of 25