____ wire, together with strain insulators, is used to support conductors in all spans exceeding 40 ft.

Free
(Multiple Choice)
4.9/5
(31)
Correct Answer:
Verified

C

An ____ is the organization, office, or individual responsible for enforcing the requirements of a code.

Free
(Multiple Choice)
4.8/5
(41)
Correct Answer:
Verified

A

A separately derived system is an electrical source, other than a service, having ____ connection(s) to circuit conductors of any other electrical source other than those established by grounding and bonding connections.

Free
(Multiple Choice)
4.7/5
(29)
Correct Answer:
Verified

C

A feeder consists of all circuit conductors located ____.

(Multiple Choice)
4.8/5
(30)

Grounded (grounding) is defined as being ____.

(Multiple Choice)
4.7/5
(29)

Wiring components are considered accessible if (1) access can be gained without damaging the structure or finish of the building or if (2) they are ____.

(Multiple Choice)
4.8/5
(42)

A multiwire circuit must consist of conductors connected to ____.

(Multiple Choice)
4.7/5
(43)

A point in a wiring system from which current is taken to supply utilization equipment is known as a(n) ____.

(Multiple Choice)
4.8/5
(32)

Panelboards having doors or covers are considered ____.

(Multiple Choice)
4.7/5
(32)

An attachment plug establishes connection between ____.

(Multiple Choice)
4.7/5
(28)

Conductors in concealed raceways, even though they may become accessible by withdrawing them, are still considered ____.

(Multiple Choice)
4.7/5
(28)

All conductors of a multiwire branch circuit must originate from ____.

(Multiple Choice)
4.9/5
(30)

A grounding electrode is a(n) ____ object that establishes a direct connection to earth.

(Multiple Choice)
4.8/5
(36)

The neutral point is the common point on a ____ in a polyphase system.

(Multiple Choice)
5.0/5
(33)

A load having the maximum level of current sustained for three hours or more is referred to as a ____ load.

(Multiple Choice)
4.7/5
(39)

"Equipment" is a general term, including fittings, devices, appliances, luminaires, apparatus, machinery, etc. used ____ in an electrical installation.

(Multiple Choice)
4.8/5
(27)

Ready accessibility to wiring in luminaires is ____.

(Multiple Choice)
4.9/5
(37)

A(n) ____ is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing.

(Multiple Choice)
5.0/5
(39)

A contact device installed at an outlet for the connection of an attachment plug is a(n) ____.

(Multiple Choice)
4.8/5
(26)

When metal parts are required to be electrically connected, a(n) ____ is installed, thereby guaranteeing the required electrical conductivity.

(Multiple Choice)
4.7/5
(28)
Showing 1 - 20 of 25