Exam 3: Boxes and Enclosures
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations19 Questions
Exam 14: Services, Feeders, and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies25 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
What is the angle pull for a raceway in the horizontal dimension where the trade size of the largest raceway is 3 and the sum of the other raceways in the same row on the same wall is 4?
Free
(Multiple Choice)
4.8/5
(24)
Correct Answer:
B
Inspection of the connections between luminaire conductors and circuit conductors must be possible without ____.
Free
(Multiple Choice)
4.8/5
(34)
Correct Answer:
A
The minimum box width for U pulls must include ____.
Free
(Multiple Choice)
4.7/5
(22)
Correct Answer:
C
Volume in boxes can be increased by using ____ rings, domed covers, extension rings, or similar items.
(Multiple Choice)
4.9/5
(32)
____ or fewer luminaire wires (smaller than 14 AWG) and an equipment grounding conductor can be omitted from box fill calculations where they enter a box from a domed luminaire (or similar canopy) and terminate within that box.
(Multiple Choice)
4.7/5
(35)
Equipment grounding conductor(s) or equipment bonding jumpers entering a box count as ____.
(Multiple Choice)
4.8/5
(42)
The maximum number of conductors applies only if the box does not contain any ____.
(Multiple Choice)
4.8/5
(33)
Supporting screws for nonmetallic boxes must be mounted ____.
(Multiple Choice)
4.9/5
(35)
Snap switches (including dimmer switches) must be connected to a(n) ____ and must also provide a means to connect metal faceplates to the equipment grounding conductor, even if a metal faceplate is not installed.
(Multiple Choice)
4.8/5
(34)
____ are permitted inside conduit bodies, if the manufacturer durably and legibly marked the cubic inch capacity on the conduit body.
(Multiple Choice)
4.8/5
(39)
Wire connectors, pigtails, locknuts, bushings, raceway connectors, grounding screws, and equipment bonding jumpers are not factors when calculating ____.
(Multiple Choice)
4.9/5
(43)
Where a box contains both straight and angle (or U) pulls, or straight pulls and splices, calculate each type of pull ____ to find the dimension.
(Multiple Choice)
4.9/5
(35)
A luminaire that weighs more than ____ pounds shall be supported independently of the outlet box, unless the outlet box is listed and marked on the interior of the box to indicate the maximum weight the box shall be permitted to support.
(Multiple Choice)
4.8/5
(31)
The weight supported by any single conduit shall not exceed ____ pounds.
(Multiple Choice)
4.9/5
(28)
Nonmetallic-sheathed cable not fastened to the box must be secured within ____ in. of the box.
(Multiple Choice)
4.9/5
(31)
No requirement specifies the depth of a box, unless a ____.
(Multiple Choice)
4.9/5
(34)
Where multiple rows of raceways enter a box, calculate each row separately and use the ____.
(Multiple Choice)
4.9/5
(39)
A 3 x 2-in. device box, 2.5 in. deep, has a volume of ____ cubic inches.
(Multiple Choice)
4.9/5
(32)
Cable connector(s) with a ____ outside the box are not counted when determining the number of conductors.
(Multiple Choice)
4.9/5
(27)
Showing 1 - 20 of 25
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)