A transformer vault door must be ____.

Free
(Multiple Choice)
4.9/5
(32)
Correct Answer:
Verified

B

A tap conductor is a ____ that exceeds the value permitted for similar conductors protected as otherwise described in 240.4.

Free
(Multiple Choice)
4.8/5
(27)
Correct Answer:
Verified

A

Knife switches rated more than ____, and at over 1000 amperes at 251 to 1000 volts, shall be used only as isolating switches and shall not be opened under load.

Free
(Multiple Choice)
4.9/5
(30)
Correct Answer:
Verified

C

The capacitor circuit conductor's ampacity shall be at least ____% of the capacitor's rated current.

(Multiple Choice)
4.9/5
(42)

Cartridge fuse and fuseholder overcurrent protection provisions are located in ____.

(Multiple Choice)
4.8/5
(41)

Barriers are required in all service-entrance motor-control centers to ____ and terminals from the remainder of the motor-control center.

(Multiple Choice)
4.8/5
(22)

Minimum ampacity of arc welder conductors supplying a group of welders shall be based on ____ as determined in 630.11(A)

(Multiple Choice)
4.8/5
(33)

Cable tray systems should be ____.

(Multiple Choice)
4.9/5
(28)

A transformer's primary conductors shall have an ampacity at least ____ of the feeder conductors' overcurrent device rating.

(Multiple Choice)
4.7/5
(22)

If a single raceway supplies an equipment grounding conductor, only one ____ equipment grounding conductor is required.

(Multiple Choice)
4.9/5
(32)

Wherever such an arrangement is practicable, transformer vaults shall be located so that ____.

(Multiple Choice)
4.9/5
(35)

If a crane, hoist, or monorail hoist operates above readily combustible material, specific requirements shall apply to ____.

(Multiple Choice)
4.9/5
(30)

Motor circuits rated 1000 volts, nominal, or less, shall have a disconnecting means with an ampere rating of at least ____% of the motor's full-load current rating.

(Multiple Choice)
4.9/5
(26)

A 60-ampere rated conductor is the minimum size allowed if the overcurrent protection on the tap conductor's line side is ____.

(Multiple Choice)
4.9/5
(38)

Means shall be provided to disconnect all conductors in a building (or other structure) from the ____.

(Multiple Choice)
4.8/5
(31)

____ branch circuits shall be protected at the motor nameplate current rating.

(Multiple Choice)
4.8/5
(42)

Where multiple power supplies serve the same dc system, the dc side of each power supply shall have a ____.

(Multiple Choice)
4.7/5
(34)

Where an orderly shutdown is required to minimize the personnel/equipment hazard(s), a system of coordination based on the following two conditions is permitted: (1) coordinated short-circuit protection and (2) ____.

(Multiple Choice)
4.9/5
(30)

The combined length of one primary plus one secondary conductor (excluding any portion of the primary conductor protected at its ampacity) shall not exceed ____.

(Multiple Choice)
4.7/5
(32)

The tap conductor's ampacity shall not be less than the ____ on the circuits it supplies.

(Multiple Choice)
5.0/5
(32)