Exam 3: Computed Radiography: Physics and Technology
Exam 1: Digital Radiography: An Overview50 Questions
Exam 2: Digital Imaging Processing Concepts50 Questions
Exam 3: Computed Radiography: Physics and Technology50 Questions
Exam 4: Effective Use of Computed Radiography50 Questions
Exam 5: Flat-Panel Digital Radiography50 Questions
Exam 6: Digital Fluoroscopy50 Questions
Exam 7: Digital Mammography50 Questions
Exam 8: Picture Archiving and Communication Systems50 Questions
Exam 9: Medical Imaging Informatics: An Overview50 Questions
Exam 10: Quality Control for Digital Radiography50 Questions
Select questions type
Energy subtraction imaging can be done in CR using a special ____________________ to create separate images of bone and soft tissue.
(Short Answer)
4.8/5
(35)
The emitted light from the CR is optically filtered and collected by the light channeling guide, or light collection optics.
(True/False)
4.8/5
(35)
Error correction ensures that equipment not meeting the performance criteria or tolerance limit established for specific QC tests must be replaced or repaired to meet specifications.
(True/False)
4.9/5
(20)
Quality control involves a number of activities that are of significance to the administrator.
(True/False)
4.9/5
(41)
The smaller the ____________________ size, the better the spatial resolution of the image.
(Short Answer)
4.8/5
(30)
The lasers used today for PSL in CR units are ____________________ lasers that produce light with a 680 nm wavelength compared to He Ne lasers that produce light with a 633 nm wavelength used in earlier CR units.
(Short Answer)
4.9/5
(38)
An image with a bit depth of ____ will have 256 (28)shades of gray per pixel.
(Multiple Choice)
4.9/5
(33)
Routine performance involves conducting a QC test on the equipment on a regular basis with varying degrees of ____________________.
(Short Answer)
4.9/5
(27)
Which of the following is a feature in an image that masks or mimics a clinical feature?
(Multiple Choice)
4.9/5
(37)
____________________ involves both sampling the analog signal and quantization.
(Short Answer)
4.8/5
(32)
The maintenance of equipment is an integral part of the daily activities in _____________________ since it is considered a component of a continuous quality improvement program.
(Short Answer)
4.8/5
(34)
The digital detector used in CR imaging is the ____________________.
(Short Answer)
4.9/5
(35)
When is the PSP IP erased by exposing it to a high intensity light beam to get rid of any residual latent image?
(Multiple Choice)
4.8/5
(34)
Once the fixed stationary IP is exposed, the ____________________ image is acquired using a scanning technology appropriate to the system.
(Short Answer)
4.7/5
(33)
In the past, gas lasers such as a helium-neon (He-Ne)laser were used; however, current CR readers use solid-state laser diodes that emit a red laser beam having wavelengths of about 670-690 nm.
(True/False)
4.9/5
(34)
Which of the following refers to X-ray exposure of the phosphor plate storage, or imaging plate (IP)?
(Multiple Choice)
4.9/5
(25)
Given the negative feedback due to underexposures, what does a predictable and unfortunate use of higher exposures result in?
(Multiple Choice)
4.8/5
(34)
The ____________________, or scanner, is a machine for scanning the exposed IP to render the latent image visible.
(Short Answer)
4.8/5
(41)
A(n)____________________ indicator is a numerical parameter used to monitor the radiation exposure to the IP in CR imaging.
(Short Answer)
4.9/5
(38)
The number of trapped electrons is proportional to the ____.
(Multiple Choice)
4.9/5
(35)