With digital imaging, automatic rescaling of the image provides images that have similar brightness (density)over an exposure range greater than ____X.
(Multiple Choice)
4.8/5
(33)
Because automatic rescaling produces images with similar brightness, it is viewed as the ____ of the system.
(Multiple Choice)
4.9/5
(26)
Currently, each major vendor uses a unique ____________________ indicator whose values indicate the exposure delivered to the plate.
(Short Answer)
4.8/5
(32)
When performing a mobile chest scan, how is the cassette normally oriented?
(Multiple Choice)
4.9/5
(41)
If the exposure is >100% above the optimal signal level, the ALARA principle is violated, and the extra scatter generated will degrade the ____________________.
(Short Answer)
4.9/5
(36)
Overexposure implies dark images and underexposure implies light images.
(True/False)
4.9/5
(32)
If the receptor is overexposed by a factor of ____, one would assume that the patient received an equally high exposure.
(Multiple Choice)
4.8/5
(35)
With CR, grid cutoff does not result in a light image, due to the automatic ____________________ of the image.
(Short Answer)
4.8/5
(32)
What would substantial (>2x)overexposure of a body part generate in proportion to the overexposure?
(Multiple Choice)
4.9/5
(28)
____ are much more susceptible to fogging than are conventional film-screen systems.
(Multiple Choice)
5.0/5
(35)
Saturation and ALARA violations are the primary reasons to use appropriate exposure level.
(True/False)
4.7/5
(29)
Except for special extremity plates from ____, all plates are basically made from the same barium fluorohalides and are coated to the same thickness.
(Multiple Choice)
4.8/5
(21)
The exposure latitude of a digital detector is substantially lower than screen-film.
(True/False)
4.7/5
(24)
Digital image acquisition decouples the relationships between exposure and image appearance via automatic rescaling and image processing algorithms.
(True/False)
4.7/5
(36)
If the exposure field is not recognized, the off-focus radiation and scatter outside the exposure field become part of the ____________________.
(Short Answer)
4.8/5
(35)
_____________________ means that the photon intensity reaching the receptor is higher than that required to produce an optimal image.
(Short Answer)
4.9/5
(37)
With screen/film imaging, the ____________________ of the effect of technical factors is normally based on the image appearance rather that on the physics behind the appearance.
(Short Answer)
4.9/5
(29)
Since the grid strips are oriented in the direction of grid tilt, grid cutoff is more likely to occur.
(True/False)
4.9/5
(33)
Because of the wide dynamic range of the PSP plate and automatic rescaling, the relationship between exposure and image brightness is ____________________.
(Short Answer)
4.9/5
(39)
The optimal alignment is field-centered to the ____________________ with four collimation margins parallel to the cassette edges.
(Short Answer)
4.7/5
(33)