Exam 25: Configuring the Ethernet Ip Address for a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e
Exam 1: Introduction to Control Logix Hardware14 Questions
Exam 2: Introduction to Rs Logix 5000 Software19 Questions
Exam 3: Number Systems17 Questions
Exam 4: Rs Logix 5000 Project Organization16 Questions
Exam 5: Understanding Control Logix I-O Addressing16 Questions
Exam 6: Modular Controllogix Digital and Analog I-O Configuration15 Questions
Exam 7: Compactlogix I-O Configuration15 Questions
Exam 8: Communicating Between Your Personal Computer and Your Plc15 Questions
Exam 9: Creating and Monitoring Rs Logix 5000 Tags15 Questions
Exam 10: Introduction to Logic15 Questions
Exam 11: The Basic Relay Instructions15 Questions
Exam 12: Controllogix Timer Instructions15 Questions
Exam 13: Adding Ladder Rung Documentation15 Questions
Exam 14: Control Logix Counter Instructions15 Questions
Exam 15: Comparison Instructions15 Questions
Exam 16: Data-Handling Instructions15 Questions
Exam 17: Introduction to the Get System Values Gsv and Set Systems Values Ssv Instructions15 Questions
Exam 18: Introduction to the Rs Logix 5000 Function Block Programming Language15 Questions
Exam 19: Configuring a Serial Driver Using Rs Linx15 Questions
Exam 20: Configuring the Keyspan by Tripp Lite, High-Speed Usb to Serial Adapter Model Usa-19hs15 Questions
Exam 21: Configuring an Rslinx Serial Driver Using a Rockwell Automation 9300-Usbs Usb to Serial Adapter15 Questions
Exam 22: Installing and Configuring a Usb Driver for 1756-L7 Series Controllers15 Questions
Exam 23: Determining and Modifying a Personal Computers Ip Address15 Questions
Exam 24: Configuring 1756 Control Logix Modular Ethernet Hardware15 Questions
Exam 25: Configuring the Ethernet Ip Address for a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e15 Questions
Exam 26: Configuring a 1756-Enet Ethernet Driver Using Rs Linx10 Questions
Exam 27: Configuring Ethernet-Ip Drivers Using Rs Linx Software15 Questions
Exam 28: Configuring a Compact Logix 1769-L23e, 1769-L32e, or 1769-L35e Ethernet-Ip Driver Using Rslinx15 Questions
Exam 29: Configuring a Usb Driver for a 1756-En2t Ethernet Communications Module12 Questions
Select questions type
To use a serial driver to view or modify a CompactLogix controller's Ethernet IP address, begin by connecting a 1756-CP3, or ____________________ cable, between the personal computer and CompactLogix controller serial port.
Free
(Short Answer)
4.7/5
(39)
Correct Answer:
null modem
The number groups in an IP address are referred to as ____________________.
Free
(Short Answer)
4.7/5
(31)
Correct Answer:
octets
DeviceNet communications require the separate purchase of the communications modules for insertion into a CompactLogix slot.
Free
(True/False)
4.8/5
(39)
Correct Answer:
True
When configuring a basic Ethernet network, the IP addresses and ____________________ in all devices on the same network must be compatible.
(Short Answer)
4.8/5
(39)
In many industrial networks, a controller's network configuration type is configured as ____________________.
(Short Answer)
4.9/5
(35)
The 1768 CompactLogix requires that separate communications modules be purchased for chassis slot insertion, as the 1768 CompactLogix controller is only available with a(n) ____________________ port.
(Short Answer)
4.9/5
(43)
The software that verifies that a serial driver is configured and running is the ____________________ software.
(Short Answer)
4.7/5
(36)
The 1769-L23s are available with embedded ControlNet communications.
(True/False)
4.8/5
(38)
A new Ethernet device comes from the factory configured as ____________________.
(Short Answer)
4.9/5
(40)
Communication with an Ethernet device using Ethernet communications is not possible until the device is configured and/or the IP address for the device is known.
(True/False)
4.9/5
(40)
The newest members of the CompactLogix family, released at the end of 2011 with version 20 of RSLogix 5000 Software, replace the standard serial port with a(n) ____________________ port.
(Short Answer)
4.8/5
(36)
For a new 1769 CompactLogix device, or if you are unsure of the Ethernet port configuration, what can be done to view, modify, or initially configure the Ethernet port?
(Essay)
4.9/5
(40)
All 1769 CompactLogix controllers are supplied with one serial and one Ethernet port.
(True/False)
4.9/5
(40)
What happens to previously configured communications to a controller if its IP address is modified?
(Essay)
4.9/5
(48)
The CompactLogix Ethernet/IP address changes frequently after installing a network and configuring other devices on the network.
(True/False)
4.7/5
(41)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)