To use a serial driver to view or modify a CompactLogix controller's Ethernet IP address, begin by connecting a 1756-CP3, or ____________________ cable, between the personal computer and CompactLogix controller serial port.

Free
(Short Answer)
4.7/5
(39)
Correct Answer:
Verified

null modem

The number groups in an IP address are referred to as ____________________.

Free
(Short Answer)
4.7/5
(31)
Correct Answer:
Verified

octets

DeviceNet communications require the separate purchase of the communications modules for insertion into a CompactLogix slot.

Free
(True/False)
4.8/5
(39)
Correct Answer:
Verified

True

When configuring a basic Ethernet network, the IP addresses and ____________________ in all devices on the same network must be compatible.

(Short Answer)
4.8/5
(39)

In many industrial networks, a controller's network configuration type is configured as ____________________.

(Short Answer)
4.9/5
(35)

The 1768 CompactLogix requires that separate communications modules be purchased for chassis slot insertion, as the 1768 CompactLogix controller is only available with a(n) ____________________ port.

(Short Answer)
4.9/5
(43)

The software that verifies that a serial driver is configured and running is the ____________________ software.

(Short Answer)
4.7/5
(36)

The 1769-L23s are available with embedded ControlNet communications.

(True/False)
4.8/5
(38)

A new Ethernet device comes from the factory configured as ____________________.

(Short Answer)
4.9/5
(40)

Communication with an Ethernet device using Ethernet communications is not possible until the device is configured and/or the IP address for the device is known.

(True/False)
4.9/5
(40)

The newest members of the CompactLogix family, released at the end of 2011 with version 20 of RSLogix 5000 Software, replace the standard serial port with a(n) ____________________ port.

(Short Answer)
4.8/5
(36)

For a new 1769 CompactLogix device, or if you are unsure of the Ethernet port configuration, what can be done to view, modify, or initially configure the Ethernet port?

(Essay)
4.9/5
(40)

All 1769 CompactLogix controllers are supplied with one serial and one Ethernet port.

(True/False)
4.9/5
(40)

What happens to previously configured communications to a controller if its IP address is modified?

(Essay)
4.9/5
(48)

The CompactLogix Ethernet/IP address changes frequently after installing a network and configuring other devices on the network.

(True/False)
4.7/5
(41)