Exam 2: The Study of Microbial Structure: Microscopy and Specimen Preparation

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

If the decolorizer is left on too long in the Gram-staining procedure, gram-positive organisms will be stained __________ and gram-negative organisms will be stained __________.

(Multiple Choice)
4.8/5
(40)

Which of the following is considered to be a differential staining procedure?

(Multiple Choice)
4.9/5
(34)

After the decolorizer has been added, gram-positive organisms are stained __________ and gram-negative organisms are stained __________.

(Multiple Choice)
4.9/5
(30)

A 30 ×\times objective and a 20 ×\times ocular produce a total magnification of

(Multiple Choice)
4.8/5
(36)

The useful magnification of a light microscope is limited by the ___________ of the light source being utilized. Section 2.02

(Short Answer)
4.9/5
(43)

Which of these microscopes can be used to create high-resolution three-dimensional images of cells?

(Multiple Choice)
4.9/5
(35)

It is possible to build a light microscope capable of 10,000 ×\times magnification, but the image would not be sharp because resolution is independent of magnification.

(True/False)
4.8/5
(34)

Mordants increase the binding between a stain and specimen.

(True/False)
4.8/5
(34)

In the Gram-staining procedure, the mordant is

(Multiple Choice)
5.0/5
(32)

In order to stain flagella so that they may be readily observed by light microscopy, it is usually necessary to increase their thickness.

(True/False)
4.8/5
(28)

In the Gram-staining procedure, the primary stain is

(Multiple Choice)
4.8/5
(37)

Atomic force microscopes use a scanning probe that maintains a fixed distance from the surface of the specimen. It is useful for specimens that

(Multiple Choice)
4.9/5
(45)

A microscope that exposes specimens to ultraviolet, violet, or blue light and forms an image with the light emitted at a different wavelength is called a __________ microscope.

(Multiple Choice)
4.7/5
(33)

Prior to staining, smears of microorganisms are heat-fixed in order to

(Multiple Choice)
4.8/5
(34)

An electron microscope uses __________ lenses to focus beams of electrons onto a specimen.

(Short Answer)
4.9/5
(34)

In the Gram-staining procedure, the decolorizer is

(Multiple Choice)
4.9/5
(41)

The designer of the first transmission electron microscope, _________________, was awarded the 1986 Nobel Prize in physics.

(Short Answer)
4.8/5
(37)

Confocal microscopes exhibit improved contrast and resolution by

(Multiple Choice)
4.8/5
(35)

A light microscope with an objective lens numerical aperture of 0.65 is capable of allowing two objects 400 nm apart to be distinguished when using light with a wavelength of 420 nm. Section 2.02

(True/False)
4.9/5
(45)

The procedure in which a single stain is used to visualize microorganisms is called __________ staining.

(Short Answer)
4.9/5
(35)
Showing 41 - 60 of 61
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)